I’m putting up a 3.8 m × 3.8 m single-storey rear extension. A 110 mm sewer runs beneath each side wall; local regulations insist on 150 mm clearance all round, so the wall will bridge the pipe with pre-stressed concrete lintels spanning roughly 410 mm between ring-beam piles. What I need from you is a concise set of structural calculations that confirms the size, type and bearing length of those concrete lintels and shows they can safely carry: • the 350 mm-wide cavity wall (block inner leaf, brick outer leaf) • the warm-deck Trocal flat roof and any maintenance load • typical domestic live and dead loads specified in current Northern Ireland Building Regulations Please include: 1. Clear summary of assumptions (masonry densities, partial safety factors, load paths, etc.). 2. Sizing check for the chosen pre-stressed concrete lintel(s) over the 410 mm gap, with capacity vs. applied load shown step-by-step. 3. Minimum bearing lengths on either side of the sewer. 4. A brief note confirming compliance with NI regs and Eurocodes. A short PDF or calculation sheet signed off (or ready for sign-off) by a chartered structural engineer is all that’s required; no full-house drawings or site visits are needed. If you have any questions about the wall build-up or ring-beam details, let me know and I’ll supply the extra info right away.
Project ID: 40512131
14 proposals
Remote project
Active 21 secs ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
14 freelancers are bidding on average £161 GBP for this job

Hi, I am a professional structural engineer with over 09+ years of experience in structural analysis and design. I have worked on similar projects and have relevant experience. I can provide you with the requisite qualitative work. Please feel free to contact me to discuss further. Thanks & regards, Ghullam Hussain P.E. (Structures)
£200 GBP in 4 days
7.4
7.4

Hi there, from your ready architectural drawings, I will prepare the structural drawings and translate them into structural drawings. My experience is over 15 years in this field. Let me show you my skills and experience. I'm ready to discuss all the project details over chat. Thanks Engineering Approach Layout Translation: Converting your 3.8 m × 3.8 m extension footprint and sewer alignments into localized structural load tracks. System Optimization: Sizing the pre-stressed concrete lintels to safely span the 410 mm gap, bridging the cavity wall and flat roof loads. Code Compliance: Verifying bearing lengths, capacity ratios, and load paths to satisfy Eurocodes and Northern Ireland Building Regulations. Phases 1. Review: Evaluating your 350 mm cavity wall build-up, Trocal roof dead loads, and maintenance live loads. 2. Analysis: Calculating dead and live load combinations to determine the exact bending and shear stresses over the sewer clearance. 3. Drafting: Translating design calculations into step-by-step capacity sheets and minimum bearing length specifications. Deliverables Calculation Package: Step-by-step structural calculations displaying applied loads versus lintel capacity ratios. Technical Brief: Documented material assumptions, masonry densities, and clear minimum bearing lengths on either side of the pipe. Compliance Statement: A concise engineering note confirming total compliance with current NI building regulations and Eurocodes. Best Regards
£110 GBP in 3 days
6.6
6.6

Hi there, I noticed that you need structural calculations and supporting documentation for pre-stressed concrete lintels spanning over sewer lines, including load assessments, bearing checks, and compliance-ready calculation sheets for Building Control review. I’ve completed fully coordinated residential extension and structural documentation projects before with similar requirements. As a skilled CAD and engineering design professional with over 7 years of experience, I specialize in providing precise, high-quality technical drawings, calculation support, and construction documentation using AutoCAD, Revit, SolidWorks, and structural detailing workflows. I also provide detailed reports, load-path reviews, and coordinated design packages tailored to approval and construction requirements. I’m happy to share relevant plans and samples upon request. This is my portfolio link: https://www.freelancer.com/u/andrasr69 I am looking forward to work with you. Best regard. Andres
£100 GBP in 3 days
3.7
3.7

Hi. I can provide structural design services for your project. I am proficient in structural analysis, design, and detailing of reinforced concrete, timber, and steel structures, I have worked with codes such as the ACI, AISC, ASCE, IBC, IRC, NDS, Eurocode, Canadian, Indian, Turkish, and Australian ones. I am skilled in analysis software, including Sap2000, Etabs, Safe, Staad Pro, Robot structures,Tekla structures, Abaqus, and Adapt Builder. I can deliver any phase of structural engineering work, including analysis, design, drafting, documentation, inspection, site supervision and estimation. Please see some projects in the portfolio, and feel free to contact me for further details or clarifications.
£150 GBP in 4 days
3.8
3.8

Hello, I am confident my expertise in Building Architecture, AutoCAD, and Civil Engineering aligns perfectly with your project's structural analysis needs for the rear extension. I understand the importance of precise load calculations, especially when bridging sewer pipes with pre-stressed concrete lintels, and I am proficient in ensuring compliance with Northern Ireland regulations and Eurocodes. I will provide a clear set of structural calculations, including assumptions, capacity checks, and bearing lengths, all signed off by a chartered structural engineer, tailored specifically for your project. My approach integrates detailed load analysis and innovative use of AutoCAD for visualization, ensuring accuracy and compliance. Please share any further details or specific requirements, and I can prepare a comprehensive, ready-for-sign-off calculation sheet promptly. Looking forward to helping you with this task. Could you clarify if there are any specific compliance standards or new regulations you want to emphasize for this project? Thanks, Gourav
£20 GBP in 1 day
1.9
1.9

Hello, I am interested in assisting with the structural assessment for your rear extension and can prepare a clear calculation package covering the proposed lintel arrangement over the sewer crossings. I have experience producing structural calculations for residential extensions, masonry support details, lintels, foundations, and Eurocode-based structural checks. For this project, I will review the wall build-up, ring-beam pile arrangement, sewer clearance requirements, and loading conditions to verify a suitable pre-stressed concrete lintel solution. The calculations will clearly identify all design assumptions, including material properties, masonry densities, dead and live loads, partial safety factors, and load paths. I will then perform a step-by-step assessment of the selected lintel size, checking bending, shear, bearing, and overall capacity against the applied loads from the cavity wall, roof construction, and maintenance loading requirements. The report will also include minimum bearing requirements, commentary on the proposed arrangement, and a concise compliance statement referencing relevant Eurocodes and Northern Ireland Building Regulations. My goal is to provide a professional, easy-to-follow document suitable for submission, review, or engineer sign-off where required. I maintain a practical approach focused on constructability, clarity, and compliance while keeping documentation concise and efficient.
£70 GBP in 2 days
1.5
1.5

Hello, I have experience preparing concise structural calculation packages for domestic extensions, masonry wall support, sewer build-over conditions, lintel checks, and Eurocode-based load assessments. This project is a good fit because you need a focused calculation sheet for a specific 410 mm sewer bridge condition, not a full drawing package. I will review the wall build-up, roof loading, ring-beam pile details, sewer clearances, and proposed pre-stressed concrete lintel arrangement, then calculate the applied loads and compare them against lintel capacity. I will provide clear assumptions, bearing requirements, step-by-step capacity checks, and a short compliance note referencing Northern Ireland Building Regulations and Eurocodes. The final PDF will be prepared for chartered engineer review/sign-off or signed where required by the appointed engineer. Thanks for reading my proposal. Edwin
£100 GBP in 7 days
0.0
0.0

Hey there! I can definitely deliver a concise set of structural calculations that confirms the size, type and bearing length of those concrete lintels. Let's connect and get rolling! Best, Eilenne
£150 GBP in 2 days
0.0
0.0

Hi, I am a Structural & Façade Engineer with strong experience preparing structural calculations, design checks, technical reports, and practical engineering solutions in line with Eurocodes, British Standards, and UK Building Regulations. I’d be happy to help with the structural calculation package needed for the pre-stressed concrete lintels.
£250 GBP in 5 days
0.0
0.0

Belfast, United Kingdom
Member since Jun 13, 2026
$1500-3000 AUD
$250-750 USD
$14-100 NZD
£250-750 GBP
$750-1500 CAD
$250-750 CAD
min $50 USD / hour
$30-250 AUD
₹1000-3500 INR
$1500-3000 USD
$250-750 USD
$10-30 USD
$30-250 USD
₹600-1500 INR
₹600-1500 INR
$30-250 CAD
$250-750 USD
$250-750 USD
$750-1500 USD
₹5000-20000 INR