
Closed
Posted
Paid on delivery
For 4200m2 single level carpark: I need a full transient CFD study that proves our basement car-park’s jet-fan ventilation system can control smoke when a single parked car catches fire. The goal is verification for the design team, so the model must be detailed enough to demonstrate airflow paths, visibility, temperature and toxic gas levels throughout the event. Please build and run the case in either ANSYS CFX or ANSYS Fluent, modelling jet fans only—no ducted supply or exhaust fans are to be represented. Use a realistic heat release rate curve for a passenger vehicle fire and carry the calculation long enough to show the post-flashover phase. Deliverables • Native solver files and exported meshes so we can rerun or tweak the case • A brief set-up note explaining boundary conditions, turbulence and radiation models, species settings and time-step strategy • Animations and high-resolution stills of velocity vectors, temperature, CO/visibility contours and smoke isosurfaces • A short results memo summarising tenability criteria (visibility, temperature <60 °C at 1.8 m, CO < 400 ppm) and confirming whether the jet fan arrangement meets our performance targets I will supply architectural drawings in DWG/PDF and fan data sheets immediately after kickoff. Please let me know your expected run time and any additional information you require before starting.
Project ID: 40800181
45 proposals
Remote project
Active 1 day ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
45 freelancers are bidding on average $5,212 USD for this job

Your carpark smoke study requires engineering judgment across geometry, thermal behaviour and CFD-oriented analysis, and my background in mechanical engineering, thermal analysis, finite element analysis and CAD/CAM is well aligned with that need. I can work from your DWG/PDF information to develop a detailed single-level carpark representation focused on the jet-fan ventilation arrangement and passenger-vehicle fire scenario. My 3D modelling and CAD experience supports accurate spatial modelling, while my thermal-analysis and mechanical-engineering skills are relevant to assessing temperature fields, airflow paths and fire-related conditions. I can also prepare clear technical visualisations, including velocity, temperature, smoke and visibility outputs, together with organised native model files and supporting documentation suitable for design-team review. I would be pleased to deliver a professional CFD study package that clearly presents the tenability assessment against your stated criteria and helps verify the jet-fan arrangement. Choose me to bring the engineering modelling, analysis and visual reporting together for this project.
$166 USD in 1 day
7.6
7.6

Hi, I’m a Mechanical Design Engineer with years of experience in mechanical engineering, CFD/FEA analysis, CAD modeling, and engineering simulation. I’m interested in supporting your 4,200 m² basement car park smoke-control study using ANSYS Fluent or CFX. My proposed approach includes: - Preparing and cleaning the architectural geometry for CFD. - Modeling the existing jet-fan arrangement and realistic operating conditions, without introducing ducted supply or exhaust fans. - Defining a passenger-car fire HRR curve, including the growth, peak, and decay phases. - Setting up transient simulations with appropriate turbulence, radiation, species transport, and combustion assumptions. - Evaluating airflow paths, temperature, CO concentration, visibility, and smoke propagation. - Performing mesh sensitivity and time-step sensitivity checks. - Producing animations, high-resolution contours, smoke isosurfaces, and solver files. - Preparing a technical report comparing results against your specified tenability criteria. I would first review the geometry and fan data, then establish the simulation methodology and estimate the computational requirements. The runtime will depend on mesh size, transient duration, and available computing resources. I look forward to reviewing your project information and discussing the schedule and quotation. Best regards,
$6,000 USD in 20 days
6.8
6.8

My team’s experience across architecture, engineering design and more than 1,000 completed projects gives me a strong foundation for developing a coordinated carpark ventilation study from your DWG/PDF information and fan data. I can prepare the required architectural and engineering geometry in AutoCAD and Revit, with 3D modelling capability for representing the single-level 4,200 m² carpark and jet-fan arrangement. My skills in 3D Modelling and CAD/CAM support accurate spatial coordination, while AutoCAD and Revit are well suited to converting your design information into a clear, reusable model. I can also provide high-quality visual outputs and technical drawings to support the requested airflow, temperature and smoke presentation. However, ANSYS Fluent/CFX transient fire simulation, species transport, radiation modelling and tenability verification are not listed in my profile, so I cannot accurately claim specialist CFD capability for this scope. I would be pleased to support the geometry, CAD coordination and presentation aspects of the project, with the CFD solver work handled by a specialist if required.
$5,000 USD in 3 days
6.8
6.8

Hi there, I can perform CFD-based car park ventilation and smoke propagation analysis using ANSYS Fluent to evaluate smoke movement, airflow distribution, temperature, and visibility under fire scenarios. I have 7+ years of CAE experience with expertise in CFD, thermal analysis, and engineering simulations. Deliverables: - 3D CFD model and computational mesh. - Ventilation and jet fan airflow analysis. - Fire and smoke propagation simulation. - Temperature, velocity, and smoke concentration contours. - Airflow and smoke extraction effectiveness assessment. - Simulation results with a detailed technical report. - Design improvement recommendations, if required. I can also assess the ventilation performance against applicable fire safety design criteria. Do you have the car park layout, jet fan locations, and fire scenario details available? Timeline and budget can be finalized after discussing the complete scope. Best regards, Arati M.
$5,050 USD in 7 days
6.8
6.8

My experience with AutoCAD, Revit, CAD/CAM and detailed 3D modelling can help convert your 4,200 m² carpark drawings into a clear, accurate simulation-ready geometry. I also work with architectural and commercial design, working drawings, BIM design and technical 3D models, which is relevant to representing the parking layout and jet-fan locations correctly. I can support the geometry preparation, mesh-ready model development and professional visual presentation of the study, including high-quality 3D renders and animations. My background includes AutoCAD, Revit, 3ds Max, Rhino, CATIA, Abaqus and other modelling tools, allowing me to work effectively with DWG/PDF information and produce organized native CAD deliverables. However, my profile does not specifically demonstrate ANSYS Fluent/CFX smoke CFD experience, so I would not misrepresent myself as the engineer responsible for validating the transient solver results, fire physics, species modelling or tenability conclusions. I would be pleased to contribute the carpark modelling, CAD preparation and visualization components of this project, while ensuring the CFD verification is handled by an appropriately experienced fire-simulation specialist.
$217 USD in 1 day
6.4
6.4

Hello, I can send you my CFD car park CO2 smoke evaluation in ansys fluent report, which I have done. Feel free to contact me
$550 USD in 5 days
6.1
6.1

I understand you require a transient CFD smoke simulation for a 4200m² carpark to verify your jet-fan ventilation system's effectiveness against a car fire. My experience with similar transient fire and smoke spread analyses, particularly in enclosed spaces, ensures a robust and accurate simulation that will provide the clear, actionable data your design team needs for verification. I will build a detailed 3D CAD model of the carpark geometry. The simulation will be performed using ANSYS Fluent, leveraging its transient solver capabilities. The jet fan performance will be accurately modeled using pressure outlet boundary conditions derived from manufacturer data or appropriate correlations. A realistic passenger vehicle fire heat release rate curve will be implemented, and species transport will be activated to track smoke and toxic gas concentrations (e.g., CO). Turbulence will be modeled using the k-omega SST model, and appropriate discretization schemes will be employed for accuracy. The simulation will run until the smoke plume either reaches a defined visibility threshold or the heat release rate naturally decays. To ensure the simulation precisely aligns with your verification needs, could you clarify the specific visibility threshold (e.g., meters) and the primary toxic gas (e.g., CO) of most concern for your design team's acceptance criteria? I am available for a brief call to discuss these details and how my approach will deliver the required insights.
$5,657 USD in 21 days
5.4
5.4

The critical question is not whether your jet fans move smoke, but whether they maintain tenable conditions throughout the fire. Jet fans redistribute smoke; without defined inlet and outlet paths, they cannot remove it from the basement. I'd first verify the ventilation boundaries, fan thrust data, and fire location before building the 4,200 m² transient model in ANSYS Fluent. My approach would use a time-dependent vehicle-fire heat release rate, buoyancy, turbulence, radiation, and CO/soot species transport. I'd refine the mesh around the fire plume, jet fans, and ceiling flows, then check time-step sensitivity before assessing temperature, visibility, and CO exposure at 1.8 m. I'm an Aerospace Engineer with an MSc in Aerodynamics, specializing in CFD, turbulent flows, and gas-turbine cooling. You'll receive native Fluent case/data files, mesh exports, setup documentation, high-resolution animations, and a results memo comparing the predicted conditions against your agreed tenability limits. I'll share the boundary-condition and fire-scenario plan for approval before committing computational resources. One key question: What openings allow fresh air and smoke to enter or leave the basement when ducted fans are excluded?
$890 USD in 6 days
5.7
5.7

I can develop a transient CFD model of your 4,200 m² basement car park using ANSYS Fluent, focusing exclusively on the jet-fan ventilation system and a realistic single passenger-vehicle fire scenario. I will evaluate airflow patterns, smoke propagation, temperature distribution, visibility, and CO concentration throughout the fire development and decay phases. The study will include appropriate turbulence, combustion, radiation, and species transport models, with a carefully selected mesh and time-step strategy. I have 12+ years of experience in CAD and engineering simulation, and I can provide a structured technical study with clear visualizations and results. The final conclusions will be based on the specified tenability criteria and simulation outcomes. Deliverables: Native ANSYS Fluent case and data files Exported computational mesh CFD setup and methodology note Transient animations and high-resolution result images Temperature, velocity, CO, visibility, and smoke contours Results memo evaluating the specified tenability criteria A few questions: Could you provide the jet-fan locations, thrust, airflow rates, and operating sequence? For a 4,200 m² transient fire CFD study, computational runtime will depend on mesh resolution, fire duration, and available hardware. I can confirm a realistic schedule after reviewing the drawings and fan data.
$250 USD in 7 days
4.7
4.7

Hi there, I'm a senior mechanical engineer with extensive experience in machine and product design. You can see my portfolio. I'm ready to help you make: ✨ Full transient CFD model using Ansys Fluent or CFX for the car fire simulation ✨ Detailed animations and high-resolution contours of smoke, velocity, temperature, and toxic gas levels ✨ Native solver files, mesh exports, and a comprehensive technical setup note ✨ Concise results memo evaluating tenability criteria, visibility, and jet fan performance targets I'm excited to work with you on your project and deliver the best results possible. I'm waiting for your message.
$2,575 USD in 1 day
4.5
4.5

⚡ YOUR CARPARK NEEDS SMOKE CONTROL PROOF, NOT JUST SIMULATION. We specialize in detailed CFD studies, particularly with transient simulations for ventilation systems in large spaces. Our experience includes optimizing airflow in complex environments, ensuring safety and compliance. What you really want is a robust analysis that not only meets design verification but also instills confidence in the safety measures under fire conditions. We'll model the jet fans accurately, using a realistic heat release curve for the fire. It's crucial to consider the post-flashover phase to accurately assess visibility and toxic gas levels as well. I personally oversee every project, ensuring clear communication and coordination among our specialists. You'll receive thorough reviews and direct updates throughout the process. MESSAGE ME, LET'S SEE IF WE'RE A GOOD FIT. Regards, Stefan Clavorn Collective
$5,000 USD in 14 days
4.3
4.3

I am a Mechanical/Mechatronics Engineering researcher with extensive experience in CFD simulations, fluid dynamics, heat transfer, and multiphysics modeling using ANSYS Fluent and COMSOL. I can develop a detailed transient CFD model of the 4200 m² basement car park to investigate fire-induced smoke propagation and the performance of the existing jet-fan ventilation system. The simulation will incorporate a realistic passenger-car fire heat release rate (HRR) curve, appropriate turbulence and radiation models, species transport, and transient boundary conditions. I will evaluate airflow patterns, smoke movement, temperature distribution, CO concentration, visibility, and tenability conditions throughout the fire scenario, including the post-flashover phase as specified. Mesh independence and time-step sensitivity studies will be conducted to establish numerical reliability. Deliverables will include native ANSYS simulation files, exported meshes, high-resolution contours, animations, and a concise technical report discussing the results against the specified safety criteria. I would be happy to review the architectural drawings and jet-fan specifications to finalize the modeling approach and estimated computational time.
$5,050 USD in 7 days
4.1
4.1

Computational Fluid Dynamics and Mechanical Engineering are directly aligned with your need for a transient carpark smoke study, supported by CAD/CAM skills for working from architectural drawings and fan-related geometry. I can coordinate an expert-led technical team to develop the ANSYS Fluent or CFX case around your single-level 4200 m² carpark and jet-fan arrangement. The requested deliverables match my capabilities in CFD and data visualization: native solver and mesh files, setup documentation, airflow and smoke visualisations, temperature, CO and visibility contours, animations, and a concise results memo addressing your stated tenability criteria. I can also organise the technical review of the vehicle-fire scenario, radiation, turbulence, species and transient simulation settings so the final package is clear and reusable by the design team. Choose me to manage this CFD assignment with the appropriate engineering expertise and deliver a professional verification package for your jet-fan system.
$400 USD in 2 days
5.3
5.3

Greetings! I can complete your transient CFD study for the 4200m2 single-level basement carpark. I will build and run the case in ANSYS CFX or Fluent, modelling jet fans only with no ducted supply or exhaust, using a realistic passenger vehicle fire heat release rate curve and running long enough to show the post-flashover phase. You will receive native solver files and exported meshes, a set-up note covering boundary conditions, turbulence and radiation models, species settings and time-step strategy, animations and high-resolution stills of velocity, temperature, CO and visibility contours and smoke isosurfaces, and a results memo assessing tenability criteria. Thanks, Revival
$100 USD in 7 days
4.1
4.1

Hello, I am Dr. Rajesh Rolen, PhD in Computer Science & Engineering, with experience of over 20+ years in Data Visualization As a preferred freelancer in the top 1%, I have done 400+ projects here on freelancer.com, I have 4.9 ratings out of 5 on average, which showcases my quality of work and timely delivery. Key Highlights: - Free Hosting Support on the Cloud or any desired platform. - Free 3 months of post-delivery support to ensure that our client doesn’t face any challenges after the launch of the project. - Free Dedicated tester on projects to ensure quality delivery, so clients don’t need to act as a tester. - 10+ Years experience UI/UX team to ensure intuitive UI. Portfolio: https://www.freelancer.com/u/Microlent Please open the chat and send me a message, so we can have a more detailed discussion about the project to give you the project timeline and cost. Thank you for considering my services. I look forward to engaging in a productive conversation and understanding how I can be of assistance in bringing your project to life. Regards Rajesh Rolen
$5,900 USD in 120 days
4.4
4.4

Hello, I’m a Mechanical Engineer with experience in ANSYS Fluent, CFD simulations, fluid flow analysis, and mechanical design. I’m interested in reviewing your 4,200 m² basement car-park ventilation project. I can contribute to the CFD model development, computational domain preparation, mesh generation, boundary conditions, transient simulation setup, and post-processing. **Proposed scope:** - 3D basement geometry and jet-fan arrangement. - Passenger vehicle fire HRR input and transient analysis. - Airflow, temperature, CO concentration, and smoke visualization. - Velocity vectors, contour plots, and simulation animations. - Organized ANSYS Fluent project files and exported mesh. - Technical documentation covering the simulation setup and results. I understand that this is a safety-critical engineering assessment. The fire model, radiation, combustion, species transport, visibility calculations, and tenability criteria require specialist validation. I would not claim that the system meets fire-safety requirements without a properly validated model and independent engineering review. Please share the DWG/PDF drawings, fan datasheets, fire scenario specifications, and applicable design standards so the scope and computational requirements can be assessed. Best regards Engr. Dawood
$334 USD in 2 days
2.3
2.3

Hi, I’d love to help bring your project to life. I’m a South African freelancer with extensive experience in CFD simulations, particularly using ANSYS CFX and Fluent. I understand the critical nature of your carpark ventilation study for verifying your jet-fan system's effectiveness during a fire event. My approach will ensure a detailed transient simulation that accurately models the airflow, temperature, visibility, and toxic gas levels. I will provide comprehensive deliverables, including native solver files, a setup note detailing all parameters, high-resolution animations and stills, and a results memo summarizing the tenability criteria. I pride myself on quality, clear communication, and reliability. Let’s have a quick chat about your needs and expectations. Worst case, you walk away with a free consultation and a clearer idea of how to move forward. Regards, Sue-Ann
$5,000 USD in 7 days
2.0
2.0

My CFD and thermal-analysis experience using ANSYS, COMSOL, ABAQUS, NX and STAR-CCM+ aligns directly with your need for a transient carpark smoke study. I work across mechanical, civil and architectural projects, combining CAD/CAE expertise with detailed 3D modelling to create an analysis-ready representation of the 4,200 m² space and jet-fan arrangement. I can prepare the native solver case and exported mesh, model the vehicle-fire thermal event and smoke behaviour, and produce the requested velocity, temperature, CO and visibility outputs. My background in Computational Fluid Dynamics, Thermal Analysis and Mechanical Engineering also supports a clear setup note covering boundary conditions, turbulence, radiation, species and transient settings, together with a concise tenability assessment against your stated criteria. I would be pleased to deliver a professional, reusable CFD package with animations, high-resolution visuals and a results memo suitable for your design team’s verification work.
$100 USD in 7 days
2.2
2.2

For this project, I can use CATIA (or SolidWorks) for modeling and ANSYS for simulation, as per your request. The estimated timeframe for the project is approximately 20 days. Once you have provided the necessary data and I have reviewed it, I will need to get in touch with you—at least once—to gather further information or to clarify any questions or uncertainties that may arise. All files, especially the source files, will be provided to you. The only potential issue concerns the software version used, which could cause complications. Please let us know if you are using a specific version.
$880 USD in 20 days
0.7
0.7

My aeronautical engineering background and hands-on experience with FEA/CFD and ANSYS make me well suited to develop a technically structured smoke-ventilation simulation for your carpark. I work extensively with engineering analysis alongside CATIA V5 and SolidWorks, giving me a strong foundation for converting architectural geometry and fan data into a usable CFD model. I can support the transient jet-fan case in ANSYS, including the passenger-vehicle fire scenario, airflow and smoke movement, temperature, CO and visibility evaluation, and clear engineering visualisations. My mechanical engineering and piping-system design experience also helps me interpret ventilation layouts and present results in a way that is useful to your design team. I will provide the native solver case, exported mesh, setup documentation, animations, stills and a concise results summary aligned with your stated tenability criteria. I would be pleased to apply my CFD and ANSYS skills to this fire-engineering verification study and deliver a professional, reusable analysis package.
$100,000 USD in 30 days
0.3
0.3

Izmir, Turkey
Member since Nov 3, 2026
$250-750 USD
$250-750 USD
₹12500-25000 INR
₹12500-37500 INR
₹1500-12500 INR
₹1500-12500 INR
$250-750 USD
₹1500-12500 INR
₹1500-12500 INR
$25-50 USD / hour
₹12500-37500 INR
$30-250 USD
$30-250 USD
$100-10000 USD
$250-750 USD
₹1500-12500 INR
$200-250 USD
$250-750 USD
₹12500-37500 INR
€30-250 EUR
$750-1500 USD
$750-1500 USD