EXPLORE

Instrumentation Product Management
Profile cover photo
User Avatar

Emission Stack Monitoring E.

@kspuri

0.0
0

0.0

0.0

0%

Oil Gas Analyzer Commissioning Training

$15 USD / Hour

・

Flag of

Saudi Arabia (8:35 AM)

・

Joined on August 7, 2010

$15 USD / Hour

・

Major training I will provide on the Enviroment Emissioning Monitoring System for Stack Gas that monitors NO, NOX, SO2, CO, O2 & H2S. Second part of training also include general maintenance of each extractive analyzer such as Teledyne and Thermo . Based on my experience you will get comprehensive training on extractive CEMS system's maintenance and repairs, so that one can easily understand the general and major problem occurs during operational flue stack gases. You will also train how to find out the sample conditioner's and inside analyzer technical fault. It will also enable to check either sample is flowing or not. Analyzer training would train you on how detect single component failure and it replacement. Other than maintenance I shall train guys on calibration and testing so as to make sure what has been done it is positive and Emissioning monitoring system is indicating data. I can help to train on the commissioning, testing, Calibration of Online & offline Water Environment Containmination as Oil in water analyzer for Crude oil in Refinery Waste Water, Multiple Hydrocarbons in Petrochemical Plant Waste Water, Sea & Drinking Water. Also available to train for Commissioning of online WaterCutt, Online Moisture , Hydrogen Sulphide , Oxymtter 4000 Analyzers associated and Corrosion with brands Turner Design Hydrocarbon instruments, Emerson, Phase Dynamics and ( Lab / field ) ACM Instruments and Environmental CEMS Stack Monitoring system like Teledyne & Thermo NO, NO2, NOX CO2 O2 CO, in this case if any body in the CEMS and want to diagnose the faults and repair the analyzer, stack & PLC problem. Gas detectors fixed and online for Oxygen, Hydrocarbon, Methane , Glycol, Hydrogen Sulphide , Benzene , can be trained. Online training can be provided on Skype or possibility in field. However if any body want to understand how to make and prepare the Chemical standard for portable analyzer TD 500 to get the proper content or concentration of oil in water then I can also support.

Verifications

Portfolio

Portfolio

9990472
9990472
0.0 · 0 Reviews
Reviews

No reviews to see here!

Experience

Sr. Analyzer Commissioning, Testing Maintenance Engineer

Dec, 2021 - Present

•

3 years, 11 months

Saudi Electric Power Plant

Dec, 2021 - Present

•

3 years, 11 months

Commissioning, Maintenance, Calibration, training of Teledyne, Thermo environment Stack Monitoring Analyzers for measurement and detection of CO, CO2, H2S, NO, NO2,NOX SO2, as approved engineer for Saudi Electric combine cycle power plant.

Dec, 2021 - Present

•

3 years, 11 months

Analyzer Instrument Oil Gas Calibration Commissioning Engineer

Jan, 2018 - Present

•

7 years, 11 months

MT

Jan, 2018 - Present

•

7 years, 11 months

Calibration, Commissioning Testing of Calibration (with Master Unit ) , Commissioning & Testing of Bently Novada Vibration Analyzer , Emerson Vibration CSIC 2140, Hydrogen Sulphide , Crude Oil in Water, Water in Hydrocarbon Flue Gas HF Laser Gas Analyzers, Calibrators , Laser Level , Carbon Monoxide, LEL detector , Oil & Water Meter , Fluke Thermocouple source meter calibration & CEMS Analyzers. Laboratory and Field HVC Chillers Maintenance.

Jan, 2018 - Present

•

7 years, 11 months

Commissioning Testing of Hydrocarbon in Sea Water Analyzers

Jan, 2008 - Dec, 2017

•

9 years, 11 months

Diversified Petroleum Services

Jan, 2008 - Dec, 2017

•

9 years, 11 months

Commissioning Testing calibration of Oil in water Analyzer , Sea Water Analyzers, Sulphur and Hydrocarbon Sulphide Analyzers in Saudi Arabia.

Jan, 2008 - Dec, 2017

•

9 years, 11 months

Education

Sir Syed University of Engineering and Technology

1995 - 1999

•

4 years

B.E

Flag of

Pakistan

1995 - 1999

•

4 years

Qualifications

ACM LPR CORROSION POTENTIOSTAT

2020

ACM INSTRUMENTS UK

Electronic maintenance Commissioning, Installation of ACM corrosion potentiostat & concrete corrosion sample testing on ACM corrosion potent Analyzer. Pipeline Corrosion Montoring , Coatng Testing was also been testedd.

2020

Hydrogen Sulfide Analyzer Commissioning Testing Servicing Maintenance

2012

KECO, Houston USA

Calibration Commissioning Testing maintenance and Operation of Online Hydrogen Sulphide in Crude Oil Process and Oil n water Analyzer, from Analytical System KECO, Houston , USA 2012.

2012

Moisture WaterCutt Analyzer

2009

PHASE DYNAMIC, Dallas, Texas, USA Water Cut Analyzers USA

32 Hours training comprising concept of RF Water & Crude oil oscillator and operation of the water cut analyzer. Operation in GOSP & refineries. Fault diagnostic, rectification, maintenance and replacement of microwave sensor. Comprehensive maintenance and commissioning with fault diagnostic

2009

Registered Users

Total Jobs Posted

Freelancer ® is a registered Trademark of Freelancer Technology Pty Limited (ACN 142 189 759)

Copyright © 2025 Freelancer Technology Pty Limited (ACN 142 189 759)